1. Application
Mobile oil purification station
SMM-0,16 is designed
for thermal vacuum degassing of lubrication and
insulating oils, whose viscosity at temperature 50 C
does not exceed 70 cSt to remove solids, water and
gases.
Station is used for mounting,
repairing and operating high-voltage oil equipment
with voltage up to 1150 kV( power transformers,
high-voltage switches etc.)
The machine complies with number
4 category placement and climatic design UHL as per
GOST 15 150-69.
Operating conditions:
-ambient temperature 283 to 308
K( +10 to+ 35)C;
-atmospheric pressure 84 to 106,7
kPa ( 630 to 800 mm.Hg);
- altitude above sea level 2000
m.;
- ex-proof premises.
2. Specifications
2.1 PRIMARY STATION
SPECIFICATIONS ARE STATED IN THE TABLE
1.
Тable
1
|
№ |
Parameter |
Value |
|
1 |
Capacity,
m3/h:
-
in degassing, drying and filtration
conditions |
0,16 |
|
2 |
Maximum oil outlet temperature under
heating,
°С |
60 |
|
3 |
Processed oil characteristics
(initial
moisture content
50
g/t)
-
mass moisture content,
g/t
-
filtration fineness,
mcm |
10,0
5 |
|
4 |
Oil feeding height referring to outlet
fitting,
m |
20 |
|
5 |
Oil heater power,
kW |
4,8 |
|
6 |
Oil heater specific surface power,
kW/сm2
|
1,1 |
|
7 |
Set power consumtion,
kW |
5,8 |
|
8 |
Three-phase VAC~50 Hz,V |
220/380 |
|
9 |
Dimensions, mm
-
length
-
width
-
height |
980
650
1550 |
|
10 |
Mass, kg |
230 |
3. Set of delivery
Table
2
|
№
|
Designation |
Quantity |
|
1 |
Mobile oil purification station SMM
ready-fitted |
1 |
|
2 |
SMM spare parts:
-
rubber crosspiece drawing.
SMM-20.00.03А
- filtering element 5 mcm
- filtering element 40 mcm
- filter
-
heating element
ТEN
|
1
1
1
3
1 |
|
3 |
Operational documentation:
-
SMM-0,16 certificate with operational manual |
1
|
|