MOBILE PURIFICATION STATION
SMM-0,6
This
document contains protected copyright
information. All the rights are reserved. Any
part of this manual can not be copied by any of
mechanical, electronic or other means without
prior Manufacturer’s written permission.
Due to
continuous improvement of the plant, certain
parts may differ from the default specification.
This will not reduce performance of the system.
1.APPLICATION
Mobile
purification station SMM-0,6 is designed for
thermal vacuum degassing of lubrication and
insulating oils, whose viscosity does not exceed
70 cSt at temperature 50 C to remove solids,
water and gases. Station is used for mounting,
repairing and operating high-voltage oil
equipment with voltage up to 1150 kV( power
transformers, high-voltage switches etc.)
The
machine complies with number 4 category
placement and climatic design UHL as per GOST 15
150-69.
Operating conditions:
-ambient temperature 283 to 308 K( +10 to+ 35)C;
-atmospheric pressure 84 to 106,7 kPa ( 630 to
800 mm.Hg);
-
altitude above sea level 2000 m.;
-
ex-proof premises.
2.
Specifications
2.1
PRIMARY STATION SPECIFICATIONS ARE STATED IN THE
TABLE
1.
Тable
1
|
№ |
Parameter |
Value |
|
1 |
Capacity,
m3/h:
-
in degassing, drying and filtration
conditions |
0,6 |
|
2 |
Maximum oil outlet temperature under
heating,
°С |
60 |
|
3 |
Processed oil characteristics
( initial
moisture content
50
g/t)
-
мass
moisture content,
g/t
-
filtration fineness,
mcm |
10,0
5 |
|
4 |
Oil feeding height referring to outlet
fitting,
m |
20 |
|
5 |
Oil heater power,
kW |
14,4 |
|
6 |
Oil heater specific surface power,
kW/сm2
|
0,5 |
|
7 |
Set power consumption,
kW |
18 |
|
8 |
Three-phase VAC~50 Hz,V |
380 |
|
9 |
Dimensions, mm
-
length
-
width
-
height |
1350
700
1600 |
|
10 |
Mass, kg |
300 |
Note-
parameters stated in the table provided for the
one operational process
3.SET
OF DELIVERY
Таble
4
|
№
|
Designation |
Quantity |
|
1
2
3 |
Mobile oil purification system SMM
ready-fitted
Component parts removed of the
station while transportating
:
-
wheels
Special key |
1
4
1 |
|
2 |
SMM spare parts:
-
rubber crosspiece drawing.
SMM-20.00.03А
-
filtering element EF-DGD
-
filter
-
heating element
ТEN
2НВР-50ДМ
spare parts:
-
cup
1,1-20х52-4
GОSТ
8752-79;
-
valve;
-
gasket
30х3;
-
gasket
9х3 |
1
2
2
4
6
1
1
1
1 |
|
3 |
Operational documentation:
- SMM-0,6
certificate with operational manual;
-
operating manual for
2NVR-50DМ
(appendix
Е) |
1
1 |
Note.
Manufacturer
allows a
customer
to choose the following products
:
-
monometer;
-
fluoroplastic filtering element with
filtration accuracy
1…5mcm