Welcome at our official site
“ Ukrbudmash Plant Ltd”
Mobile oil purification stations
SММ-1,0;
SММ-1,7;
SММ-2,2;
SММ-4,0
This document contains
protected copyright information. All the rights
are reserved. Any part of this manual can not be
copied by any of mechanical, electronic or other
means without prior Manufacturer’s written
permission.
Due to continuous improvement
of the plant, certain parts may differ from the
default specification. This will not reduce
performance of the system.
1.
APPLICATION
Stations are designed for
thermal vacuum degassing of lubrication and
insulating oils whose viscosity at temperature
50 C does not exceed 70 cSt to remove gases,
water and gases.
Stations are used for
mounting, repairing and operating high-voltage
oil equipment with voltage up to 1150 kV( power
transformers, high-voltage switches etc.)
The machine complies with
number 4 category placement and climatic design
UHL as per GOST 15 150-69.
Operating conditions:
-ambient temperature 283 to
308 K( +10 to 35)C;
-atmospheric pressure 84 to
106,7 kPa ( 630 to 800 mm.Hg);
- altitude above sea level
2000 m.;
- ex-proof premises.
2.
SPECIFICATIONS
2.1
Primary specifications are stated in the table 1.
Table 1
|
№
|
Parameter |
Value |
Value |
Value |
Value |
|
SММ-1,0 |
SММ-1,7 |
SММ-2,2 |
SММ-
4,0 |
|
1 |
Capacity,
m3/h
-
in degassing, drying and filtration
condition
-
in filtration condition |
1,0
1,0 |
1,7
1,7 |
2,2
2,2 |
4,0
4,0 |
|
2 |
Мaximum
oil outlet temperature under heating
condition,
°С |
60 |
60 |
60 |
60 |
|
3* |
Processed oil characteristics:
- bulk
gas content,
%
-
mass moisture content,
g/t
-
filtration fineness,
мcм
|
0,1
5,0
5 |
0,1
5,0
5 |
0,1
5,0
5 |
0,1
10,0
5 |
|
4 |
Oil feeding height referring to
outlet fitting,
m |
20 |
20 |
20 |
20 |
|
5 |
Oil heater power,
кW |
14,4 |
27 |
30 |
36 |
|
6 |
Oil heater specific surface rower,
kW/сm2 |
1,1 |
1,1 |
1,1 |
1,1 |
|
7 |
Set power consumption,
кW |
21,5 |
36 |
45 |
50 |
|
8 |
Three-phase VAC~50 Hz,V |
380 |
380 |
380 |
380 |
|
9 |
Dimensions,
mm
-
length
-
width
-
height |
1500
1000
1550 |
1500
1050
1700 |
1500
1050
1700 |
1550
1100
2050 |
|
10 |
Мass,
кg |
600 |
550 |
1000 |
1100 |
Note
- *
Parameters stated in the table
can be reached within 1 processing cycle
under the following
characteristics of initial oil:
-
bulk gas content no more than
10,5%;
-
mass moisture content no more
than
50
g/t.
**
The station can be custom
manufactured with filtration degree 1mcm of
processed oil.
2.2
Transformer
oil
physicochemical
testing
ratio after processing
is stated in the table
2.
Таble
2
|
№
|
Ratio list of transformer oil
physicochemical testing
|
Transformer oil
after processing
|
Test
methods |
|
1 |
Viscosity ,
50 0 С |
2 |
|
|
2 |
Ignition temperature in closed
crucible,
0
С |
135 |
GОSТ
6356 |
|
3 |
Acid number,
мg
КОN
in 1g of oil |
0,1 |
GОSТ
5985 |
|
4 |
Visual water content |
absent |
|
|
5 |
Water-soluble acids content,
mg
КОN
in
І
g of
oil |
0,014 |
GОSТ
6307 |
|
6 |
Punch-through voltage,
кW |
55 |
GОSТ
6581 |
|
7 |
Dielectric loss tangent of angle,
90 0
С |
0,2 |
GОSТ
6581 |
|
8
|
Solids content,
% from mass (g/t) |
absent |
GОSТ
6370
RТМ
17216 |
Note
–
Oil after processing on SMM
complies with operational oil by reduced
physicochemical testing.
2.3.
Transformer oil testing ratio on gas content via
GH method
after
processing
is stated in the table 3
Таble
3
|
№
|
Gas name |
Density
% |
|
1 |
Hydrogen |
0,01 |
|
2 |
Carbon monoxide |
0,02 |
|
3 |
Меthane |
0,01 |
|
4 |
Carbon dioxide |
0,3 |
|
5 |
Ethylene |
0,01 |
|
6 |
Ethane |
0,005 |
|
7 |
Аcetylene |
0,001 |
|
8 |
Oxygen |
- |
|
9 |
Nitrogen |
- |
3.
SET OF DELIVERY
Таble
4
| |