Welcome at our
official site “ Ukrbudmash Plant Ltd”
Mobile oil purification stations
SММ-1,0;
SММ-1,7;
SММ-2,2;
SММ-4,0
(trailer-mounted)
This
document contains protected copyright
information. All the rights are reserved. Any
part of this manual can not be copied by any of
mechanical, electronic or other means without
prior Manufacturer’s written permission.
Due
to continuous improvement of the plant, certain
parts may differ from the default specification.
This will not reduce performance of the system.
1.
APPLICATION
Stations are designed for thermal vacuum
degassing of lubrication and insulating oils
whose viscosity at temperature 50 C does not
exceed 70 cSt to remove gases, water and gases.
Stations are used for mounting, repairing and
operating high-voltage oil equipment with
voltage up to 1150 kV( power transformers,
high-voltage switches etc.)
The
machine complies with number 4 category
placement and climatic design UHL as per GOST 15
150-69.
Operating conditions:
-ambient temperature 283 to 308 K( +10 to 35)C;
-atmospheric pressure 84 to 106,7 kPa ( 630 to
800 mm.Hg);
-
altitude above sea level 2000 m.;
-
ex-proof premises.
2.
SPECIFICATIONS
2.1
Primary specifications are stated in the table 1.
Table 1
|
№
|
Parameter |
Value |
Value |
Value |
Value |
|
SММ-1,0 |
SММ-1,7 |
SММ-2,2 |
SММ-4,0 |
|
1 |
Capacity,
m3/h
-
in degassing, drying and filtration
condition
-
in filtration condition |
1,0
1,0 |
1,7
1,7 |
2,2
2,2 |
4,0
4,0 |
|
2 |
Мaximum
oil outlet temperature under heating
condition,
°С |
60 |
60 |
60 |
60 |
|
3* |
Processed oil characteristics:
- bulk
gas content,
%
-
mass moisture content,
g/t
-
filtration fineness,
мcм
|
0,1
5,0
5 |
0,1
5,0
5 |
0,1
5,0
5 |
0,1
10,0
5 |
|
4 |
Oil feeding height referring to
outlet fitting,
m |
20 |
20 |
20 |
20 |
|
5 |
Oil heater power,
кW |
14,4 |
27 |
30 |
36 |
|
6 |
Oil heater specific surface rower,
kW/сm2 |
1,1 |
1,1 |
1,1 |
1,1 |
|
7 |
Set power consumption,
кW |
21,5 |
36 |
45 |
50 |
|
8 |
Three-phase VAC~50 Hz,V |
380 |
380 |
380 |
380 |
|
9 |
Dimensions,
mm
-
length
-
width
-
height |
1500
1000
1550 |
1500
1050
1700 |
1500
1050
1700 |
1550
1100
2050 |
|
10 |
Мass,
кg |
600 |
550 |
1000 |
1100 |
Note
- *
Parameters stated in the table
can be reached within 1 processing cycle
under the following
characteristics of initial oil:
-
bulk gas content no more than
10,5%;
-
mass moisture content no more
than
50
g/t.
**
The station can be custom
manufactured with filtration degree 1mcm of
processed oil.
2.2
Transformer
oil
physicochemical
testing
ratio after processing
is stated in the table
2.
Таble
2
|
№
|
Ratio list of transformer oil
physicochemical testing
|
Transformer oil after processing
|
Test
methods |
|
1 |
Viscosity ,
50 0 С |
2 |
|
|
2 |
Ignition temperature in closed
crucible,
0
С |
135 |
GОSТ
6356 |
|
3 |
Acid number,
мg
КОN
in 1g of oil |
0,1 |
GОSТ
5985 |
|
4 |
Visual water content |
absent |
|
|
5 |
Water-soluble acids content,
mg
КОN
in
І
g of
oil |
0,014 |
GОSТ
6307 |
|
6 |
Punch-through voltage,
кW |
55 |
GОSТ
6581 |
|
7 |
Dielectric loss tangent of angle,
90 0
С |
0,2 |
GОSТ
6581 |
|
8
|
Solids content,
% from mass (g/t) |
absent |
GОSТ
6370
RТМ
17216 |
Note
–
Oil after processing on SMM
complies with operational oil by reduced
physicochemical testing.
2.3.
Transformer oil testing ratio on gas content via
GH method
after
processing
is stated in the table 3
Таble
3
|
№
|
Gas name |
Density
% |
|
1 |
Hydrogen |
0,01 |
|
2 |
Carbon monoxide |
0,02 |
|
3 |
Меthane |
0,01 |
|
4 |
Carbon dioxide |
0,3 |
|
5 |
Ethylene |
0,01 |
|
6 |
Ethane |
0,005 |
|
7 |
Аcetylene |
0,001 |
|
8 |
Oxygen |
- |
|
9 |
Nitrogen |
- |
3.
SET OF DELIVERY
Таble
4
|
№
|
Designation |
Quantity
|
|
1 |
Mobile oil purification system SMM
ready-fitted |
1 |
|
2 |
SMM spare parts:
-
rubber crosspiece drawing SММ-20.00.03А
-
filter element
-
filter
-
heating element
ТEN
110
А
АVZ-20D
spare parts:
-
disk
-
cup
1.2-40х60-1
-
cup
1.2-45х65-1
-
ring
-
spring
-
spring
-
plate
-
gasket
-
gasket
Accessories to
АVZ-20D:
-
pulleys and eccentrics lifter |
3
2
6
4
1
2
1
3
1
1
1
2
2
1 |
|
3 |
Operational documentation:
-
certificate with operational manual,
SMM;
-
operating manual,
АVZ-20D
(appendix
Е) |
1
1 |
Note.
Manufacturer
allows a customer to choose the following
products:
-
timing device;
fluoroplastic filtering element
with filtration accurancy
1…5mcm